Device Configuration
Check your device and proceed to the sections below to configure your device.
Ingenico Devices
To update any configuration files on theINGENICO
devices, the LLT tool (5.5.0) is used (supplied by INGENICO). If you do not have this tool please contact INGENICO.
- To update the files on the
INGENICO
devices, the device must be in LLT mode.- To put the INGENICO iUC285 device in LLT mode, hold the circular button on the back of the device until the light is red. The screen will display "LLT".
- For the INGENICO iPP320 & INGENICO iPP350 - restart the device and HOLD F3 until the device displays LLT.
- For the Ingenico Tetra Lane - restart the device and HOLD # until the device displays LLT
- For SELF devices, restart the device and hold the button on the back of the device until the light is red. The device will boot into LLT mode and the screen will display "LLT".
- Open the LLT tool, select the target terminal (your device will be listed), and connect the device
- In the LLT tool navigate to DEVICE_NAME/LLT_DEVICE_NAME (for IPP, IUC devices navigate to the extracted directory)
- Right-click on DEVICE_NAME.M## file and click download (for IPP, IUC devices right-click on .OGZ file and click download)
- Wait until the status says 100%
- Once loaded, double click on the device icon to disconnect (the device will take a few minutes to process this update)
- If the device displays a key injection option, select NO Key Injection and Delete KIA
- Once the device displays “This lane closed”, put the device into LLT mode again and load all configuration files from the configuration files directory: EMVCLESS.XML, EMVCONTACT.XML, tips.K3Z, and CB5BTTDES5.PGZ
If the
INGENICO iPP320, INGENICO iPP350
or Lane device displays KEY INJECTION menu after loading .OGZ file please select "NO KEY INJECTION". Delete RKI ? "YES".
*All the files inside the package can be loaded all at once except .OGZ RBA file which is required to be loaded separately. Once the OGZ file (the RBA package) is loaded the device needs to be restarted. Once restarted place the INGENICO
device into LLT mode again and the rest of the files can be loaded all at once.
PayconexPlus
are as follows;
- .OGZ file - Contains full RBA/UPP package.
- EMVCONTACT.XML - EMV configuration file.
- EMVCLESS.XML - contactless configuration file.
- tips.K3Z - required by the SDK to display prompts on the device.
- KIACFG.txt - used to disable key injection (applicable only to iUC285).
- PROMPT.XML - contains all required strings
IDTech Devices
Config instructionsThe Device MUST have the correct test key injected.
If you are running an old firmware on any of the following IDTech TEST Devices
and would like to update the firmware on the device yourself, please download the latest TEST FIRMWARE
that we support here .
Please follow the instructions listed below your device.
AUGUSTA
or MINISMART
, the test Firmware for these devices can be updated by installing the dot NET SDK Demo application. Please download the latest version of this tool from IDTech here.
- Open the IDTech dot NET SDK Demo Tool.
- using this tool you can check what firmware is loaded onto your device.
- open the dot NET SDK Demo with device connected - expand device section - firmware version - execute command.
- to obtain the extended firmware version on the AUGUSTA or MINISMART - expand device section - send data command 7831 and ensure the wrap NGA checkbox is checked.
- To update the firmware.
- expand device section - click on "Update Device Firmware".
- navigate to the correct file downloaded from above for your device and click OK.
- "Firmware Update Successful" - your device has been updated.
VP3300
or VP8300
, the test Firmware for these devices can be updated by installing the NEO application supplied in the folder you have downloaded for your device here.
Please follow these steps:
- Install NEO download application supplied in the folder.
- make sure your device is connected via USB.
- please ignore the NO COM PORT warning and select OK (this will show when connecting via USB).
- Select LOAD.
- please select the correct firmware file for your device contained in the same folder.
- window will display "100% Done and Rebooting".
- Update Successful - your device has been updated.
VP5300
or VP6300
, the test Firmware for these devices can be updated using the bootloader tool supplied in the folder you have downloaded here.
Please follow these steps:
- Open the Bootloader tool supplied in the folder for your device.
- Please check the Select All CheckBox.
- Select Update.
- Select Continue.
- Wait for all files to fully update. Status will show Completed.
- Update Successful - your device has been updated.